Batch log and status message writing¶
clsBatchBase gives batch applications a small set of output methods so status and error text goes to the correct destination — standard output, standard error, or one of up to five environment-variable-configured log files — without each application managing StreamWriter instances itself.
| Field | Value |
|---|---|
| Operation ID | OP-CA-004 |
| Trigger | Downstream batch application code calls WriteStatusMsg, WriteErrorMsg, or one of the WriteAppLogMsg overloads |
| Inputs | Message text (String); optionally a BatchStreams target (StandardFile, File0…File4) |
| Outputs | Text written to Console.Out, Console.Error, or an open file stream; for file streams, an opened/updated System.IO.StreamWriter tracked in the instance's internal log table |
| Primary components | clsBatchBase.WriteStatusMsg, clsBatchBase.WriteErrorMsg, clsBatchBase.WriteAppLogMsg (both overloads) |
| Entry point | Presentation\SAIF.Presentation.ConsoleApplication\clsBatchBase.vb |
Steps¶
- Write a status message (
WriteStatusMsg). Writes the given text toConsole.OutviaConsole.WriteLine. Used internally byWriteBatchHeader/WriteBatchFooteras part of the console application execution lifecycle. - Write an error message (
WriteErrorMsg). Writes the given text toConsole.ErrorviaConsole.Error.WriteLine. - Write a console-only application-log message (
WriteAppLogMsg(AppLogMsg)). Writes the given text directly toConsole.Out; no file or stream is involved. - Write a stream-targeted application-log message (
WriteAppLogMsg(AppLogMsg, LogFile)). Resolves the target from theBatchStreamsenum value's upper-cased name (LogNo): - If
LogNo = "STANDARDFILE": unconditionally opens a newIO.StreamWriterat{CurrentDirectory}\{AppName}.log, replacing any previously tracked writer for this stream, then writes and flushes the message (BR-006). - If
LogNois any other stream name (File0…File4):- Reads the environment variable named
LogNo. - If that environment variable is empty/unset: throws
Exception("Log stream " & LogNo & " is not a valid environment variable or file.")(BR-001). - On failure: the exception propagates uncaught out of
WriteAppLogMsg(the internalTry/Catchre-throws via a bareThrow). - If the environment variable is set and no
StreamWriterhas been opened yet for this stream (the tracked value is still its placeholder empty string): opens a newIO.StreamWriterat the path named by the environment variable and tracks it. - If a
StreamWriterwas already opened for this stream in a prior call: reuses it without reopening. - Writes the message to the resolved
StreamWriterand flushes it immediately.
- Reads the environment variable named
- Streams remain open until teardown. Any
StreamWriteropened by step 4 stays open (to allow further appends) untilclsBatchBase.Uninitialize()flushes and closes it as part of the console application execution lifecycle.
Process flow¶
The following diagram visualizes how WriteAppLogMsg(AppLogMsg, LogFile) resolves and writes to its target stream.
flowchart TD
Start([WriteAppLogMsg called<br>with message and LogFile]) --> IsStd{LogFile is<br>StandardFile?}
IsStd -->|Yes| NewStd[Always open a new StreamWriter<br>at CurrentDirectory AppName.log]
IsStd -->|No| EnvCheck{Environment variable<br>for stream is set?}
EnvCheck -->|No| ThrowErr([Throw: not a valid<br>environment variable or file])
EnvCheck -->|Yes| Opened{StreamWriter already<br>opened for this stream?}
Opened -->|No| NewNamed[Open new StreamWriter<br>at env-var path]
Opened -->|Yes| ReuseNamed[Reuse existing StreamWriter]
NewStd --> Write[Write line and flush]
NewNamed --> Write
ReuseNamed --> Write
Write --> End([Stream stays open<br>until Uninitialize])
Failure and edge-case behavior¶
- Writing to a non-
StandardFilebatch log stream whose environment variable is unset or empty throws an exception rather than silently discarding the message (BR-001). - Repeated writes to the
StandardFilestream each open a brand-newStreamWriterover the same path instead of reusing the one from the previous call, unlike the named (File0…File4) streams, which are opened once and reused (BR-006). WriteErrorMsgwrites toConsole.Erroronly — it never writes to a file-backed stream, even when the application also has batch log streams configured.- The internal log table only tracks streams that were pre-registered during
Initialize()(names matchingFILE?) or theStandardFileslot; aBatchStreamsvalue with no corresponding pre-registered environment variable still throws per BR-001 when first written to.*
Note: Statements marked with
*were inferred from code structure, naming conventions, or contextual evidence where direct confirmation was not available in source artifacts.
Related documentation¶
Sources¶